ASA has produced position statements on the best practices for proper shotcrete placement. To date, position statements have been issued by the ASA Board of Directors, Underground Committee, and Pool & Recreational Shotcrete Committee. These statements have also been published in our trade magazine, Shotcrete.
- #1 – Compressive (Strength) Values of Pool Shotcrete
- #2 – Definitions of Key Shotcrete Terminology
- #3 – Sustainability of Shotcrete in the Pool Industry
- #4 – Watertight Shotcrete for Swimming Pools
- #5 – Monolithic Shotcrete for Swimming Pools (No Cold Joints)
- #6 – Forming and Substrates in Pool Shotcrete
- #7 – Curing of Shotcrete for Swimming Pools
- #8 – Steel Reinforcement for Shotcreted Pools
Collected Resources
Previously published shotcrete articles which provide a summary of reference material of interest to specifiers:
- Background Behind the Revisions to ACI 506.2, “Specification for Shotcrete”
- Bond Strength of Diaphragm—Shotcrete Interface in Vertical Direction for AWWA D110, Type III Tanks
- Guide to Shotcrete
- Recent and Ongoing Research and Development Results in Shotcrete Technology
- Service-Life Prediction of Shotcrete
- Shotcrete Underground Applications (Axel Nitschke)
- Shotcrete Today – NOT your Father s Gunite (Charles Hanskat)
- GeoStabilization International
- Putzmeister
- South Shore Gunite Pools & Spas Inc
- Sprayforce Concrete
- Superior Gunite
- Thorcon Shotcrete & Shoring
*Members, do you have helpful technical information about shotcrete on your website to share with the ASA community? If so, email your link to [email protected] for consideration!
Industry Resources
- ACI PRC 506 – Shotcrete – Guide
- ACI PRC 506.1 – Fiber-Reinforced Shotcrete – Guide
- ACI SPEC 506.2 – Specification for Shotcrete
- ACI PRC 506.4 – Guide for the Evaluation of Shotcrete
- ACI PRC 506.5 – Specifying Underground Shotcrete – Guide
- ACI PRC-506.6 – Visual Shotcrete Core Quality Evaluation- TechNote
- ACI PRC-506.7 – Shotcrete Preconstruction Mockup—TechNote
- ACI PRC-506.8 – Shotcrete Use in Pool Construction – Guide
- ACI CCS-4 – Shotcrete for the Craftsman
- ACI CP-60 – Shotcrete Nozzleman Craftsman Workbook
- ACI CP-61 – Shotcrete Inspector Reference Package
- Additional ACI Shotcrete Resources
- C42/C42M – Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of
- Concrete
- C1385/C1385M – Standard Practice for Sampling Materials for Shotcrete
- C1140/C1140M – Standard Practice for Preparing and Testing Specimens from Shotcrete Test Panels
- C1141/C1141M – Standard Specification for Admixtures for Shotcrete
- C1550 – Standard Test Method for Flexural Toughness of Fiber-Reinforced Concrete (Using Centrally
- Loaded Round Panel)
- C1604/C1604M – Standard Test Method for Obtaining and Testing Drilled Cores of Shotcrete
- C1609/C1609M – Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)
- 110.1 – Guide Specifications for Structural Concrete Repair
- 320.1R – Guideline for Selecting Application Methods for the Repair of Concrete Surfaces
- 320.2R – Guide for Selecting and Specifying Materials for Repair of Concrete Surfaces
- 320.5R – Pictorial Atlas of Concrete Repair Equipment
- Manual for Railway Engineering – Chapter 8 Concrete
- Working Group 12 – Sprayed Concrete Use – See WG 12 Publications