Shotcrete Incorporated into ACI 318-19 Building Code

Since the shotcrete process originated well over 100 years ago, improvements in materials, equipment, and placement techniques have enabled it to become a well-proven method for structural concrete placement. The efficiency and flexibility of shotcrete have been used to great advantage in sizable structural projects, as the high-velocity impact inherent in the process provides the compaction needed to turn low-slump concrete into freestanding vertical and overhead placements with minimal formwork.

Performance of Synthetic Sheet Waterproofing Membranes Sprayed with Steel Fiber-Reinforced Shotcrete

The recent Position Statement #2, “Spraying Shotcrete on Synthetic Sheet Waterproofing Membranes,” published by the ASA Underground Committee, pointed out many aspects critical to successful performance and raised some potential issues affecting the placement.1 In the position statement, specific techniques are presented to prevent problems such as delamination, voids, or fallouts. In the discussion, the potential issue of steel fiber-reinforced shotcrete (FRS) causing damage and potentially puncturing the membrane was raised. From the experience of the committee and the available information, it was concluded that: • The forces acting on the fiber are not strong enough to push the fiber into the membrane; and • The fibers tend to orient parallel to the membrane on impact, thus reducing the risk of damage. In parallel, a research project on this subject had been undertaken at Université Laval’s Shotcrete Laboratory, with the results only recently available. This article presents the results of this investigation.2 It is intended to support ideas presented in the ASA position paper and to help in the decision-making process when dealing with waterproofing membranes and FRS in underground projects.

Fiber-Reinforced Shotcrete Applications and Testing Overview

The addition of fibers to concrete and mortars as reinforcement is not a new concept. The ancient Egyptians used straw to reinforce mud bricks for use in structures like the core walls of the pyramids. During the first century AD, the Romans incorporated horsehair fibers in the construction of structures like the Coliseum to help prevent drying shrinkage cracking of the concrete. In the modern era, the first scientific studies on the use of steel fibers to reinforce concrete date back to the 1960s and 1970s.1,2 The use of steel fiber-reinforced shotcrete (FRS) was first introduced in the 1970s.3 The first documented use of FRS was in 1973 by the U.S. Army Corps of Engineers in a tunnel adit project at the Ryrie Reservoir in Idaho. Soon thereafter it became well recognized that soil and rock excavations could effectively be stabilized with steel FRS and its use and acceptance increased globally. In the mid-1990s, the use of macrosynthetic fibers in shotcrete was developed and has increased with particular success in temporary support in underground mines where large deformation capacity is desired. Since the 1970s, thousands of projects have been successfully completed using fibers as reinforcement, including shotcrete, slabson-ground, composite steel decks, slabs-on-pile, and precast elements.

The Newly Launched ACI Shotcrete Inspector Certification Program

The Shotcrete Inspector Certification program began out of the need in the industry to have knowledgeable individuals inspecting shotcrete projects. Shotcrete contractors often find themselves having to educate project inspectors on the details needed for quality shotcrete placement. Shotcrete is a superior placement option in many cases, yet unfortunately, the expertise in evaluating the work is often non-existent. Many contractors and specifiers are faced with situations on jobsites where the lack of shotcrete-specific knowledge from the inspector has either limited the use of shotcrete or created potential litigious situations. The industry needs a knowledgeable on-site inspector, not necessarily an expert in contract documents or even a laboratory tester. As is the case with form-and-pour concrete, an inspector who has demonstrated basic shotcrete knowledge will

Improving Shotcrete Inspections

Shotcrete is a placement method for concrete. Even though the shotcrete process is over 100 years old, it constantly evolves and today, it is a modern, costeffective, and more sustainable method of concrete placement. Those of us who regularly shotcrete a variety of work will at times have inspections and therefore have to work with inspectors. Understanding the inspector’s role as a safeguard or agent for the owner is important. However, we often find dealing with inspectors can be a cumbersome part of our job. Knowing how to do something properly and being able to fully explain the means and methods of a specialized process (shotcrete) to someone who has little to no firsthand experience are two completely different animals

 

 

Common Test Panel Mistakes

Frequently, shotcrete contractors are required to shoot test panels at the beginning as well as throughout projects. Several tests are performed from these panels; however, compressive strength testing is the most common. This article will primarily address compressive strength testing. At some point, every contractor has missed a required break strength on a core extracted from one of their panels. Frequently, those bad results are not caused by bad material or poor workmanship. They are caused by poor test panel handling and improperly performed test standards. Often, the causes of those bad test results could have been easily avoided. Let’s discuss some of the more common test panel mistakes witnessed in the field

Membership Information:

USD

Payment Information:


Credit Card Information:

Format - XX
Format - XXXX

Billing Information:

Please make sure the information below matches the billing information on the credit card.
Street Address, P.O. box,


I live in a 10-story condo building built in the 1960s. The entire building is made of gunite. We use masonry drill bits for holes, but nothing seems to grip well. We have tried concrete screws, metal drywall anchors (which seem to work the best), and a plethora of other anchors and screws, but nothing seems to work. They all cause mushrooming and they either don’t grip or turn the wall to powder. What are the best tools to affix things to the walls?

Shotcrete is a placement method for concrete. Dry-mix shotcrete (the old tradename is gunite) using proper materials, equipment, and application techniques should have easily been able to reach a strength of 4000 psi (28 MPa) in the first month. After 10 years in-place the concrete should be even stronger. The level of concrete strength developed by quality shotcrete should easily accommodate drilling in anchors or concrete screws. In my experience it would have been highly unusual to build an entire 10-story building with shotcrete even in the 1960s. I’d suggest based on the extremely weak material properties and the wall turning to dust what you think is shotcrete may be sprayed plaster or stucco. Those materials don’t have near the same strength as shotcrete and would exhibit many of the problems you have mentioned.

The ASA Buyers Guide provides a detailed listing of the products and services offered by our Corporate Members.

Top Shot Concrete Inc
3807 Arthur Rose Avenue, Saskatoon, SK S7P 0C7, Canada

View Details

Sustaining Member

Torshot Construction Limited
5369 Maingate Drive, Mississauga ON, L4W 1G6 Canada

View Details

Tri State Gunite, L.P.
101 Sterling Mine Road, Sloatsburg NY, 10974 United States

View Details

US Concrete Products LLC
16 Greenmeadow Drive, Ste 202, Timonium MD, 21093 United States

View Details

Valley Crew Contracting Ltd
21375 Old Yale Road, Langley BC, V3A 4M6 Canada

View Details

Sustaining Member

Valme North America Inc.
2701 Nicholas Road, Franksville WI, 53126 United States

View Details

Vancouver Shotcrete & Shoring Inc
35920 South Parallel Road, Abbotsford BC, V3G 2K4 Canada

View Details

Sustaining Member

Vortex Companies
16945 Northchase Drive #2200, Houston TX, 77060 United States

View Details

West Maui Construction
72 Lauo Loop Ste 101, Kahului HI, 96732 United States

View Details

Western Grater Contracting LTD
2015 Millstream Road Unit # 2095, Victoria BC, V9B 6E2 Canada

View Details

Sustaining Member

Western Shotcrete Equipment
3026 S Scott Ln # 5096, West Haven UT, 84401 United States

View Details

Western Specialty Contractors
7401 Alabama Avenue, St. Louis MO, 63111 United States

View Details

Wiseman Shotcrete
120 W Gravois Ave, St. Clair MO, 63077 United States

View Details

World Domes
4355 N Haroldsen Drive, Idaho Falls ID, 83401 United States

View Details

Wurster Engineering & Construction Inc
34 Carrie Drive, Greenville SC, 29615 United States

View Details

Zolula (Pty) Ltd
26 Quantum Street Carpe Diem C10, Techno Park Stellenbosch, 7600 South Africa

View Details