Project Name:
Where Pour in Place Stops
Location:
Blowing Rock, NC
Shotcrete Contractor:
Revolution Gunite
Architect/Engineer:
Waterforge, Inc
Material Supplier/Manufacturer:
Revolution Gunite
Equipment Manufacturer:
Gunite Supply & Cementech
General Contractor:
Artisan Pools and MBI Builders
Project Owner:
Krista Biggard
Project Name:
Grotto Falls Lagoon
Location:
British Columbia, Canada
Shotcrete Contractor:
Oceanrock Art Ltd.
Architect/Engineer:
Kontur Geotechnical
Material Supplier/Manufacturer:
Cardinal Concrete
Equipment Manufacturer:
Putzmeister
General Contractor:
Oceanrock Art Ltd
Shotcrete is a placement method for concrete. As the lazy river is a long concrete trough that is intended to be functionally watertight, the best guidance is ACI, 350-06 Code Requirements for Environmental Engineering Concrete Structures. As the predominate stresses in the horizontal direction result from shrinkage and temperature, Section 7.12.2.1 provides guidance on joint spacing based on the provided reinforcement ratio in the concrete section. The closer the movement joints, the less reinforcement required. Chapter 5 of ACI 350.4R-04, Design Considerations for Environmental Engineering Concrete Structures, has guidance on design of joints for water containing structures to help maintain water tightness.
In North Carolina, we are quite fond of our local swimming holes. Ask any Tar Heel, and they will assuredly regale you with tales of their childhood spent swinging wildly from ropes and jumping from or sliding down boulders. The swimming hole always held magic for us when we were small, with water that glowed with microscopic fool’s gold, and tiny fish that would nibble at our feet. It was a place where we could run, jump, and splash, all while nature was busily oiling the wheels of our young imaginations. It’s a scene that one North Carolinian couple wished to recreate for their grandchildren, right in their backyard.
It was early November and I was on top of a mountain, at the halfway point of a project that would take 18 months to complete. This is the moment I got a call to help build a swamp, indoors, for a movie set on the coast. We get all sorts of odd requests, but this was a different kind of strange. Without further ado, I said, “Sure, sounds great, when do you need it?” The studio replied, “By Thanksgiving,” as filming was starting the following week. This sort of answer required a little more digging
Spray-crete is NOT shotcrete. Shotcrete is high-velocity placement of concrete in thicker structural sections. It appears Spray-crete is a low-velocity sprayed mortar product generally applied in a very thin layer to provide texture to an existing concrete substrate. Since you mentioned the underlaying concrete pad was cast and then the Spray-crete added the cracking could well be originating in the underlaying concrete. Concrete cracks for a variety of reasons, such as drying shrinkage, thermal volume change (summer/winter cycles), inadequate curing, insufficient reinforcing steel, or settlement of the subgrade. You should locate a local professional engineer experienced in concrete slab evaluation who can evaluate your site, materials used, application techniques, and potential causes of the cracking. You may find the Florida Engineering Society and ACEC-FL has a list of firms who offer evaluation services.
Gunite is the original tradename for what we now call dry-mix shotcrete. Shotcrete is a placement method for concrete, so recommendations for curing and protection follow general ACI guidelines for exposed concrete. ASA recommends a minimum of 7 days of continuous (not just a few times a day) wet curing to help control shrinkage issues, increase strength, and reduce permeability in young concrete sections. Lack of curing and exposure to windy, hot, or dry conditions will certainly increase the potential for shrinkage and cracking of the concrete. Lack of curing will prevent the concrete from achieving its maximum potential strength.
Shotcrete placement with quality materials and proper application techniques generally exceeds the minimum 4000 psi 28-day compressive strength ASA recommends. The statement that 3000 psi is the “industry standard” is not true, as the ACI 350 Code for concrete liquid-containing requires a minimum 28-day compressive strength of 4000 psi for concrete intended to have low permeability when exposed to water. The required strength depends on the pool design. If you want to confirm the compressive strength of your in-place concrete, cores taken from the pool should be tested for compressive strength by a qualified testing lab. ASTM C1604/C1604M provides guidance on taking cores from existing structures. A minimum 3 in. (76 mm) diameter core is recommended. Before coring, it is recommended to use ground-penetrating radar (GPR) or similar equipment to identify the location of reinforcement in the pool section, and then take cores to avoid cutting through the reinforcement wherever possible. The core holes would then need to be filled with a high-strength, non-shrink cementitious grout. Once you learn the actual strength, you would need to check with the pool design engineer to verify the strength is adequate for the design. If the strengths are not adequate, you should consult with the pool designer or a licensed professional engineer experienced in pool design for potential solutions.
Regarding cracking, the lack of curing will increase the concrete’s shrinkage and correspondingly the potential for cracking. You should verify that there are no significant cracks in the pool shell before the plaster or other interior coating is applied. If there are cracks, the pool contractor should repair those before proceeding with the plaster or coating. Although proper curing would certainly decrease the concrete’s permeability, generally good-quality shotcrete with proper placement and a strength of 4000 psi will be functionally watertight and not allow any significant amount of water to flow through the uncracked concrete thickness. You will find more detailed information on pool compressive strengths and watertightness of pool shells in our ASA Position Statements.
Shotcrete is a placement method for concrete. Both wet-mix and dry-mix produce quality in-place concrete when using quality materials and proper equipment and placement techniques. There are no compatibility problems with shooting wet-mix over dry-mix. Basically, it is just shooting shotcrete on top of already placed concrete. For proper bond, the surface of the existing dry-mix must be roughened, cleaned, and brought to a saturated surface-dry moisture condition before shooting the wet-mix lining.
Shotcrete is a placement method for concrete. Thus, evaluating your pool shell life expectancy will be the same as any concrete structure exposed to water. You may find the technical document ACI 201.1R-08, “Guide for Conducting a Visual Inspection of Concrete in Service,” helpful in evaluating your pool shell. Generally, shotcreted concrete that uses quality materials, proper equipment, and placement techniques will serve for at least 50 to 60 years. ACI 350-06, “Code Requirements for Environmental Engineering Concrete Structures,” states: “When all relevant loading conditions are considered, the design should provide adequate safety and serviceability, with a life expectancy of 50 to 60 years for the structural concrete.” This ACI 350 Code is for liquid-containing concrete structures such as tanks for water and wastewater treatment but the original pool design may or may not meet the Code requirements.
Shooting shotcrete against a one-sided form (what you called a temporary wall) is a common way to build a shotcrete wall. Once the shotcrete sets and builds strength, the plywood form can easily be stripped off the back of the wall. Form release agents (not oil) can be applied to the plywood to make the stripping easier. Once the forms are removed and the concrete has gained adequate strength, the walls can be backfilled with compacted soil or gravel, depending on the drainage needs.
We recommend 7 days of curing. Continuous water curing is best, but if impractical, applying a curing compound on the exposed surface at twice the manufacturer’s recommended rate for a good seal is acceptable. If they remove the forms before 7 days, they should also water cure or apply curing compound to that newly exposed surface. The shotcrete needs to build up enough strength to resist the external force of the backfill, so check with the pool designer to see what they need for the required strength of the concrete before backfilling. With most good-quality shotcrete materials and placement techniques, you can expect about 4000 psi (28 MPa) compressive strength in 7 days.