Shotcrete Rehabilitation of a Vancouver, BC Historic

A heritage high-rise building in Vancouver, Canada required rehabilitation due to corro­sion of the steel frame and cracking in the masonry infill. Brick masonry was segmentally removed from the face of this 15-story-high building to expose the steel beam and column framjng system. Steel corrosion products were removed by needle scaling and sandblasting. New steel plate was welded to the beams and columns where required to strengthen the structure to its original design. Rebar was installed in the previously brick-filled cover to the steel frame and a high quality, low permeability silica fume shotcrete was applied to encase the rebar and fill the void. The south side of the building was

Seismic Reinforcing of Masonry Walls With Shotcrete

Photos and newsclips show­ing hundreds of collapsed homes bury­ing entire families have become all too commonplace. As residents of North America we are thankful that this sort of calamity doesn’t happen here. The earth­quakes we’re used to seeing (mainly in California) cause inconvenience and in some cases property damage, injury and even some deaths, but nothing as cata­strophic as in Turkey this year and Azerbaydzhan a few years back.

Bond Strength of Shotcrete Repair

A good concrete or shotcrete repair must possess three prime char­acteristics: 1) the repair material must be durable in an aggressive environment, 2) the repair must be well bonded to the substrate and 3) the repair must be as crack free as possible to efficiently protect any embedded steel reinforcement from corroding.

Repair of Bridge Elements Using Shotcrete

This article presents the essential elements nec­essary for successful remediation of bridge elements. It should be noted that all struc­tural elements whether f om bridges or other struc­tures can have certain commonality. However, with bridges, there are certain environmental character­istics that enhance the potential for distress. Bridge elements have a certain sensitivity to damage caused

Rehabilitation of Sanitary and Storm Sewers Using Shotcrete

The infrastructure of the United States is crumbling above, below, and around us. A considerable segment of the public and private engineering community is currently engaged in solving a geo­metrically increasing problem with geometrically decreasing funds. The problem is often compounded since maintenance of public works facilities must be paid for using public funds. This article will introduce a process for solving these problems that has actu­ally been around for many years-the process of using shotcrete or gunite to rehabilitate old, damaged, or otherwise substandard existing sewers.