RepairQ I am a civil engineer looking to use shotcrete in a culvert rehabilitation project. Due to flow constraints, we are forced to have a maximum wall thickness of 3 in. (76 mm). For the typical 96 in. (2438 mm) precast concrete culvert, the walls are approximately 9 in. (228 mm). What can I do to obtain a near similar product with only 3 in. (76 mm) of wall thickness? Can shotcrete be applied at higher compressive strengths, 10 psi (0.07 MPa), or is it better to use fiber-reinforced shotcrete? The intent of the retrofit is to at least obtain a 10-year service life to this temporary solution.
This is an engineering question, not an application question. Precast pipe is sized for multiple uses and services. Depending on this service (depth of cover or loads), creative reinforcing bar placement and higher compressive strengths can reduce the wall thickness significantly. For example, success has been realized using elliptical steel to reduce concrete section thickness. Fiber reinforcement is secondary reinforcing and is not a suitable replacement for reinforcing steel. Given the short life required of the culvert, and assuming fairly equal loading on the circumference, a 3 to 4 in. (76 to 101 mm) section with judiciously placed reinforcing bar, and silica fume (8 to 10% of cement for higher strength up to 10,000 psi (69 MPa)]) would be sufficient. The resulting culvert’s life would probably be much longer than 10 years. In the end, an engineering call should be made, but the material will perform.